IEPE Piezo Force Sensors
General-purpose · tension & compression50 N–45 kN compression requests. IEPE voltage output. Final selection requires model confirmation.
Review QPF-208 selection →Quartz piezoelectric force sensors, force rings and preloaded links for press-fit monitoring, stamping and impact testing. Select the sensor, mounting and signal chain around your force pulse.
Choose the mechanical form first, then check pulse duration, force direction and the input your DAQ or PLC actually accepts.
50 N–45 kN compression requests. IEPE voltage output. Final selection requires model confirmation.
Review QPF-208 selection →2–400 kN compression requests. Charge or IEPE configuration. Final selection requires model confirmation.
Review QPF-RNG selection →5–300 kN compression requests. Charge or IEPE configuration. Final selection requires model confirmation.
Review QPF-LNK selection →500 N–220 kN peak-force requests. IEPE or charge configuration. Final selection requires model confirmation.
Review QPF-IMP selection →100–100,000 pC input-range requests. ±10 V / 0–10 V / 4–20 mA options. Final selection requires model confirmation.
Review QPF-AMP selection →Range envelopes describe selection requests, not released QPF datasheets. Geometry images are concepts.
A center bolt keeps the quartz ring compressed, but also bypasses part of the incremental force. Select preload from the exact sensor and hardware instructions. Around 20% of nominal force appears in some manufacturer guidance; it is not a universal QPF setting.
Check total compression with preload, tensile unloading, contact faces and bolt stiffness. Calibrate the installed assembly. Torque alone is not a direct measurement of preload.
Explore a preloaded QPF-LNK assembly →Read the mounting and bandwidth guide →A high-impedance quartz signal needs a charge amplifier, clean connectors and qualified low-noise cable. Review temperature and drift at the assembly level.
Plan a charge measurement chain →Built-in electronics need constant-current excitation with adequate compliance voltage. Cable capacitance and current still matter for large fast signals.
Check your IEPE channel →Kistler 90xx/93xx, PCB 208C/201B and Dytran references can start a review. A matching connector or force range alone does not establish interchangeability.
Send the full model suffix, drawing, sensitivity, polarity, preload and acquisition details. Request a documented configuration comparison before releasing the order.
Open the cross-reference checklist ↗Include the peak force and pulse duration, your mounting space and existing DAQ. For replacements, add the complete original model and sensitivity.
Request a configuration quote, CAD availability and the calibration documentation you need.
[email protected]No checkout or automatic purchase. Accessory amounts are optional planning references; dimensions, compatibility, price and delivery require confirmation.